category:energy / date:2023-03-06 00:15:30 / browse:184 / comment:3

Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.The foaming technology of polyurethane with strong stability makes it have superior bonding performance. The firm combination of polyurethane rigid foam and carrier layer is the basic premise to ensure the stability of external insulation layer. That is under the unfavorable local temperature and humidity conditions, it can bear various internal and external combined loads such as wind force, self weight and normal collision, and the insulation layer still does not separate and fall off from the carrier layer and remains stable in the state.Livingston,For the selection of air conditioning units, increase the proportion of outdoor cold air and achieve the effect of energy saving.The equipment is built according to the application requirements of low-temperature distribution. It is reflected in the following points: a low-temperature hall, a closed platform, an electric sliding refrigerated door, an anti-collision flexible seal, and a platform height conditioning equipment (lifting channel) are built to complete & ldquo; Door to door & rdquo; Type loading and unloading operation has become a symbol of modern cold storage.Mobaye,The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel, which is made by high pressure foaming process and can be made into various lengths and specifications to meet the different requirements of the users.During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.


LivingstonQuick freezing and cold storage installation worksIndustry outlet



Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Specific functional characteristics of fresh machine.Connect the refrigeration system. Wires and copper pipes shall be used to connect the refrigeration unit, electric control system and other components of the cold storage. The connecting pipes shall be closely connected, and corresponding thermal insulation and protection measures shall be taken.technological innovation,The drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.The drainage at the outlet of the cooling fan, the drainage of the volatile cooler and the road drainage of the refrigerated warehouse storing food or drinks shall not be immediately connected with the sewage and wastewater pipeline system software, but indirect drainage shall be adopted. For the flushing (thawing) water drainage of each layer in the double-layer cold storage, an exhaust valve equipment shall be set in front of the main riser for flushing (thawing) water drainage.During the production of cold storage, the cold storage will produce fixed length, width and thickness according to the needs of various cold storage projects. Generally, cm thick cold storage plates are selected for high and medium temperature cold storage. The requirements for cold storage engineering plates of low-temperature storage and quick-frozen storage will be higher. Professional cold storage installation, installation, construction, fruit fresh-keeping cold storage and medical cold storage ensure the quality, Guarantee service. Guarantee quality. Your satisfaction is our pursuit! Welcome to inquire. In this case use cm or cm thick library board. When you budget the cold storage project, you can make a reservation according to the specific conditions of your cold storage temperature. If you don't make a reservation for the cold storage plate, the foaming density of cold storage is per cubic meter


LivingstonQuick freezing and cold storage installation worksIndustry outlet



As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage,LivingstonCold storage machine plate installation, so as to achieve the purpose of cooling.Welcome calls ,Fault phenomenon: fan motor overload, fan deformation; Fan motor fault; Fan motor thermal relay fault (aging); Loose wiring; Cooler blocked; Large exhaust resistance. Cold storage fault phenomenon: dryer does not operate, fuse is blown, thermal relay acts, high voltage switch acts, compressor is locked, line is falsely connected or loose fault phenomenon: it stops in a short time after drying, ambient temperature is too high, condenser is blockedThe installation of refrigeration pipeline requires that the diameter of copper pipe shall be selected in strict accordance with the interface of compressor suction and exhaust valve. When the separation between condenser and compressor exceeds M, the pipeline diameter shall be increased.The use of large-scale cold storage is naturally very strict in installation and material selection. Therefore, in the face of the above possible situations we can strictly screen the insulation board materials of cold storage, which can effectively alleviate or solve the above problems. However, at present, there are many fields using cold storage insulation board, so the details of the use environment should be considered for the wood making of many such products in the market.Livingston,Panel types of quick freezing warehouse: color plastic steel plate,LivingstonInstallation of food cold storage project, salted steel plate, stainless steel plate, embossed aluminum, etc.What should be considered in building a cold storage? In these aspects, food cold storage is a systematic project of artificial refrigeration to ensure food quality and reduce food decay in a low-temperature environment. Refrigeration technology affects the design of food cold storage, meets the needs of refrigeration technology, convenient production, energy saving and cost reduction. What problems should be considered in the construction of food cold storage?The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition, it shall be conducive to production

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

 Articles that may be of interest

Comment area

share 3 Comments

user 466HP159575805 / 2023-03-06 09:11:04 / reply
The manager is nice! LivingstonQuick freezing and cold storage installation works is also real.
user 35HP162657470 / 2023-03-06 08:30:40 / reply
LivingstonQuick freezing and cold storage installation works How's the market trend recently, do you know anything?
user 263HP145816628 / 2023-03-06 07:25:11 / reply
The festival is coming soon, can LivingstonQuick freezing and cold storage installation works be discounted?