category:energy / date:2024-02-20 02:58:38 / browse:43 / comment:4

After the cold storage at the corner is installed,LanguireVegetable fresh-keeping storehouse, the next cold storage can be installed along the direction of the corner. Adopt the similar installation of Zhang cold storage to install the thermal insulation board of the storage. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, advanced technology, more affordable price and more preferential. Welcome to consult. Pay attention to its compactness and continuous uniformity.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.Languire,The exhaust temperature of the compressor in the fresh-keeping warehouse can be read out from the thermometer on the exhaust pipeline. It is related to the adiabatic index, compression ratio and suction temperature of refrigerant. The higher the suction temperature, the greater the compression ratio, the higher the exhaust temperature, and vice versa.All wiring shall be neat. All switches and keys shall be opened and closed sensitively, reliably and accurately. Special connectors shall be used for wiring, and power protection shall be provided for the box and each power branch.Janakpur,Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate, cm or cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.Refrigeration system: refrigeration system is the core part of cold storage design. It is the key to determine the economy, environmental protection and performance of cold storage.Moreover, polyurethane does not produce harmful gas at high temperature.


LanguireWhich one is good for cold storage installationDevelopment Curriculum



The three-dimensional automatic cold storage adopts a computer, which can complete the loading,LanguireCold storage installation contract, unloading and stacking in the storage the control of storage temperature and the operation of refrigeration equipment.The set values of various protective devices of the unit have been adjusted by the factory. Users are not allowed to change them at will.Some cold bridge prevention measures shall be taken at the joints between polyurethane insulation boards.knowledge,Cold storage plate features: good thermal insulation performance, light weight, high strength, corrosion resistance, anti-aging, beautiful appearance.Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.Acid disinfectant can be used for mold removal and disinfection of quick-frozen warehouse.


LanguireWhich one is good for cold storage installationDevelopment Curriculum



Cold storage, compressor overload, lack of refrigerant, low pressure too low, excessive air intake, compressor jamming.property right,Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves, the frost flushing water return pipeline must be equipped with U-shaped bend water seal, and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.If ammonia compressor is used, a special one shall be designated and the exhaust temperature shall be strictly controlled. When high pressure is applied, subsection shall be adopted to reduce the pressure differenceFrozen and refrigerated storage began to change to shelf and pallet storage to complete the goods according to & ldquo; First in first out & rdquo; It is conducive to improve the quality of commodity storage and reduce loss.Languire, which are different. For a long time, it provides various cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage, on-site settlement, honest operation, and has offices all over the country for long-term cooperation. Different purposes, functions and designs, so what needs to be understood in cold storage design?Simple refrigeration is based on the volatilization of refrigerant in the condenser of the cold storage,LanguirePrice of medical cold storage project, so as to cool the refrigerant, and then input the refrigerant into the box or building of the refrigeration equipment to cool the air according to the heat exchanger. This kind of refrigeration has slow cooling speed, large total heat conduction temperature difference and complex system software, so it can only be used in less places, such as brine ice making and cold storage with constant temperature requirements.Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, tighten the angle iron the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

 Articles that may be of interest

Comment area

share 4 Comments

user 881HP198728332 / 2024-02-20 10:59:46 / reply
The stuff is really good, but LanguireWhich one is good for cold storage installation the price is a bit more expensive, but it is still worth the money. This is the first time I bought it, thanks to your shopping guide.
user 224HP159430236 / 2024-02-20 11:13:42 / reply
LanguireWhich one is good for cold storage installationYes, give you a good comment
user 535HP136858825 / 2024-02-20 11:28:01 / reply
Really a good seller. I have to find you if I have this LanguireWhich one is good for cold storage installation demand in the future!
user 717HP127443542 / 2024-02-20 10:57:06 / reply
In anticipation, I finally waited for my beloved LanguireWhich one is good for cold storage installation, I wish the boss a prosperous business and wealth!