Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.During the cold storage commissioning, special personnel shall be assigned to ensure that the surface of the cold storage plate shall reflect evenly without condensation and cold running; Sealing conditions of joints and holes; Whether the warehouse door and delivery port are not tightly sealed, and timely deal with the problems of insulation and seal failure such as degumming and air leakage.San Jose,For the selection of air conditioning units, it is necessary to consider the condensation pressure and other related problems of the unit, increase the proportion of outdoor cold air, and achieve the effect of energy saving.Install the library body. Generally, the warehouse body can be divided into small warehouse body and large warehouse body. The small warehouse body is basically a combined cold storage assembled with warehouse plate. The large warehouse body is mostly a civil cold storage. The assembled or constructed warehouse body is generally required to be flat, compact and solid, without hollow feeling, load-bearing antifreeze, moisture-proof, etc.Kongoussi,Whether there is dirt on the condenser and poor heat dissipation will lead to too high condensation pressure of the refrigerator. In order to protect the compressor, the machine stops running under the action of the pressure controller. When the heat dissipation is good, press the black reset button on the pressure controller, and the machine can automatically resume operation.Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.
Various construction materials, such as material certificate, test report and stage acceptance record, shall be carried out simultaneously with the project construction, carefully, timely, accurately and comprehensively reflect the whole process of production and construction, and actively cooperate with the owner in design change and technical negotiation.The electrical equipment of the fresh-keeping warehouse equipment shall be prevented from moisture return to prevent it from being caused by power failure.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Manufacturing cost,Installation of unit electrical box: the unit electrical box shall be installed near the unit; Vertical installation. If the unit is installed on the top of the warehouse, the distance between the box bottom and the top of the warehouse must be & amp; gt; mm; The electrical box can be fixed on the building wall or on the angle steel frame.Cold storage has good fire and flame resistance. After adding flame retardant, polyurethane is a kind of flame retardant and self extinguishing material. If it is burned by fire, it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be closed as a whole after fire prevention treatment to form non combustible products.The installation of cold storage board is a link of the cold storage installation project. High price cold storage installation of various specifications, cold storage installation, cold storage construction, medical cold storage. Waste merchants, industry, enterprises and power departments are welcome to visit and negotiate! The cold storage body and storage plate include: floor,San JoseUndertake cold storage installation, vertical plate and ceiling plate. The installation of storage plates in different directions and precautions are as follows: enter the construction site, verify the construction situation according to the construction drawings, determine the equipment installation position, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, the end steel sheet at the overlap with the wall plate shall be disconnected for mm to prevent the cold bridge from running cold; Two layers of foaming materials shall be evenly and continuously punched on the joint surface between each top warehouse plate. Rivets shall be pulled and fixed at the internal and external lap joints of the steel plate, and the rivet spacing shall be mm; According to the design drawings if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.High quality brand,Before the acceptance and delivery of the project the board surface shall be wiped clean. If there is any scratch, it shall be treated. There shall be no obvious scratch on the board surface.The volume of the controlled atmosphere warehouse the size of the controlled atmosphere warehouse shall be calculated according to the volume occupied by the storage products stacked in the controlled atmosphere warehouse, plus the aisle between rows the space between the stack and the wall and ceiling, and the gap between the packaging. After determining the capacity, the length and temperature of the controlled atmosphere warehouse shall be determined. The design of the controlled atmosphere warehouse shall also consider the necessary auxiliary buildings and facilities such as workshop Packing and sorting room, tool warehouse and loading and unloading platform, so that the quality of controlled atmosphere warehouse can be guaranteed.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).San Jose,The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.The butt joint between the top warehouse plate and the end of the top warehouse plate shall be treated to prevent air leakage and cold running. After all the top warehouse plates are installed,San JoseCold storage installation, the butt joint shall be filled with foaming material, and the mm wide color steel plate shall be sealed at the butt joint with pull riveting.
share 3 Comments
Comment / Cancel reply