category:energy / date:2022-11-30 02:00:15 / browse:192 / comment:5

In order to prevent damage to the cold storage, under the unfavorable local temperature and humidity conditions the characteristics of the cold storage still do not separate and fall off from the carrier layer and remain stable under normal conditions.Media Luna, due to high labor intensity and incomplete defrosting, it has limitations.The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.Tea grass,Points of multi-storey cold storage: small, which can save land; When the storage capacity is the same,Media LunaHow much is the installation of small cold storage, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room the attic on the top floor can be built into the ice making room, etc.In fact, there are some unique installation skills when installing the cold storage? The cold storage installed according to these skills is often short in both effect and quality, and the specific installation skills of the cold storage will also make some relatively detailed introduction for you in the following article. When installing the cold storage, you should install it from the corner first. Later, according to the height of the cold storage, make a hole in the middle of the insulation board,Media LunaWhich is a good cold storage design and installation, and tighten the angle iron parts until there is a hole on the insulation boardThe type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example, the cold storage that only circulates vegetables can only build a fresh-keeping cold storage, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of -kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about .-..


Media LunaCold storage engineering installation manufacturerShock prices can



The height of the warehouse, the horizontal and vertical of the warehouse shall be designed according to the refrigeration, refrigeration equipment, transportation and stacking conditions. The selection of insulation board is very important for Guangdong cold storage. At present,Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include mm, mm, mm, mm and mm polyurethane thermal insulation boards, stainless steel plates, salt thick steel plates, etc. on both sides or single and double sides, more general color steel tiles are produced and processed into hidden grooves, which have light weight, high compressive strength, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases, and it is also easy to deform and damage the appearance.Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking, every ℃ increase in the evaporation temperature of the cold storage can save energy by ~ . Therefore, on the premise of meeting the refrigeration process of the product, the liquid supply can be adjusted to increase the evaporation temperature as much as possible.Cold storage has good water tightness. Polyurethane rigid foam has low water absorption,Media LunaInstallation telephone of fresh-keeping cold storage, good permeability to water vapor, foam holes, disconnected and closed porosity of more than %. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.


Media LunaCold storage engineering installation manufacturerShock prices can



Step of cold storage design: selection and laying of cold storage thermal insulation materials. The use of cold storage thermal insulation materials must be adjusted to the time, which not only has excellent fire resistance, but also has high cost performance. There are several types of cold storage insulation materials. One is the plate produced and processed into a fixed shape and specification, with fixed length, total width and thickness. The cold storage plate with relative specification and model can be selected according to the installation of the warehouse body. The high and medium temperature cold storage generally adopts cm thick cold storage plate, cm or cm thick cold storage board is generally used for ultra-low temperature cold storage and freeze-cleaning cold storage; Another kind of cold storage can be sprayed with polyurethane spray paint and polyurethane foam, and the raw materials can be sprayed into the brick or concrete warehouse of the cold storage to be built immediately. After shaping, it is both waterproof and thermal insulation. Thermal insulation materials include polyurethane, polystyrene grease, etc. Polyurethane is non hygroscopic and has good fire resistance, but the cost is high; Polystyrene resin has strong water absorption capacity and weak fire resistance, but the cost is low.Where can I find it?,The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.With frequent goods in and out and large throughput, a special tally room (area) shall be set up according to the needs of production and operation. The temperature in the tally area is usually ~ + ℃.Moreover, polyurethane does not produce harmful gas at high temperature.Media Luna,Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor and state of foam pores. It is not connected with each other, and the obturator rate is more than %. It is a dense microporous foam material, which is more dense than the surface of the air, and is not easy to permeate. It is an hydrophobic material.Secondly, since the cooling of the compressor is not continuous, the multi work operation at night can be selected if possible. When working at night, the external temperature is low, the cooling water temperature is reduced, and the condensation pressure and condensation temperature are reduced. The cooling capacity of the sampling system, coupled with the equal role of the cold storage board, reduces the power operation of the compressor and achieves the purpose of energy saving.Able to withstand the harsh local climate and its changes. Neither high temperature nor severe cold climate will cause irreversible damage or deformation to the external insulation system. The drastic change of the surface temperature of the external wall, such as the sudden shower after a long time of exposure, or shading during exposure, will not cause damage to the surface of the cold storage.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

 Articles that may be of interest

Comment area

share 5 Comments

user 466HP159575805 / 2022-11-30 10:09:34 / reply
Media LunaCold storage engineering installation manufacturer It was posted very quickly, really timely, please give me a thumbs up
user 416HP186602172 / 2022-11-30 10:59:16 / reply
Your service is very good, Media LunaCold storage engineering installation manufacturer is also very cheap! I will come often in the future!
user 122HP117294921 / 2022-11-30 10:32:11 / reply
Buying things online is about integrity, and you do it! Thank you Media LunaCold storage engineering installation manufacturer Like one Fast delivery, very good attitude, very satisfied! very good!
user 717HP127443542 / 2022-11-30 10:30:55 / reply
Media LunaCold storage engineering installation manufacturerHow much is it, can I transfer the goods?
user 409HP184720764 / 2022-11-30 10:30:27 / reply
Media LunaCold storage engineering installation manufacturer Tell me a price, is there a detailed price for the parameter?

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links