category:energy / date:2024-01-16 09:37:53 / browse:75 / comment:4

Points of multi-storey cold storage: small which can save land; When the storage capacity is the same, the surface area of the outer enclosure structure is smaller than that of the single-layer cold storage, so that the cold consumption can be reduced, the dry consumption of food can be reduced, and the machinery and equipment cost and operation and management cost can be reduced accordingly. At the same time, due to the saving of thermal insulation materials, the civil construction cost per unit area is low and the investment cost is small; The multi-storey location can be reasonable, such as the cooling room can be used as the cold storage room, the attic on the top floor can be built into the ice making room, etc.The ground insulation of small, medium and large cold storage is different, which is closely related to the purpose, storage products and size of cold storage. Kuhua refrigeration reminds: ground insulation must be done, otherwise the temperature in the cold storage often fluctuates frequently due to poor insulation performance, which affects the quality of stored goods. So, what is the difference between the ground insulation of small, medium and large cold storage? How to do better?Kuchowe,However, not all controlled atmosphere reservoirs can choose to adjust with a large depth, which still needs to be determined according to the actual needs of fans and places. We can adjust the energy-saving effect of the control fan from the production design link, coupled with the user's energy-saving effect of the hot air fan, so that the energy-saving effect of the hot air fan will be significantly improved.When using the cold storage, try to keep the ground clean and professional cold storage installation,Armadale,Fire retardant, flame retardant and high temperature resistant polyurethane is a kind of flame retardant self extinguishing material after adding flame retardant. Its softening point can reach more than ℃, and it will decompose only at higher temperature. In addition, polyurethane forms carbon deposits on the surface of the foam, which helps to isolate the foam below. It can effectively prevent flame spread.Polyurethane foam foam dimensional stability: cold storage polyurethane foam in severe temperature changes or at a relatively low temperature will appear dimensional changes (as contraction), the size changes often reflect bubble cracking or falling off, and these will inevitably affect the normal use of cold storage. In addition to regular simulation of performance testing, more emphasis is placed on the selection of high quality materials: special energy polyether compound use, so that the foam body mesh structure, greatly improving the foam low temperature resistance. At present, polyether commonly used in spraying materials contains a large number of functional components, and a large number of linear structures formed after reaction are difficult to be stable at low temperature; The use of the energy crosslinking agent also greatly improved the dimensional stability of the foam. The selected polyether adopts catalysis in the production stage, and the reaction is complete, so that the polyether maintains a high reaction rate (that is, it can react completely with black material); Some manufacturers in order to achieve foam appearance does not produce deformation phenomenon and add a hole component to foam material, reduce the bubble closed hole rate achieve the effect of stable size, but it has sacrificed the thermal insulation performance of polyurethane cold storage insulation material foam.The installation of top warehouse plate should be carried out alternately with the installation of wall plate, and the wall plate should leave a gap for withdrawing construction equipment; During the installation of the top warehouse plate, and the rivet spacing shall be mm; According to the design drawings, if there are supporting beams, columns and supporting steel frames in the warehouse, the setting out and positioning shall be carried out and accurate and clear marks shall be made according to the requirements of the design drawings; Weld or install the support beam, column, support steel frame, etc., and the welded junction shall be moisture-proof and treated according to the drawing requirements.


KuchowePharmaceutical logistics cold storageWhat are your skills



Disadvantages of single-layer cold storage: large; The surface area of the external enclosure structure of the cold storage is large so the amount of thermal insulation materials is large, and the dry consumption of cold food is also large; For the low-temperature warehouse, the floor anti freezing treatment requires a large amount of work. When the cold storage is built at the water level, it is impossible to deal with it, which is easy to cause horizontal freezing and swelling.Wires should not be in the open air to avoid long-term sun exposure and wind blowing,KuchoweCold storage installation and maintenance, wire skin aging, long-term cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage medical cold storage without turnover, so as to avoid price difference, and the price is % higher than the market price! The price of more than one ton is higher! Short circuit, etc.Cold storage board, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation,KuchoweWhere is the company that installs cold storage, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Promise and keep promise,The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.The assembled cold storage body often adopts double-sided color steel plate of polyurethane thermal insulation material, which has excellent thermal insulation performance, storage and circulation effect and reduces operation energy consumption. Of course, more important is the choice of refrigeration system. For example, at present the refrigeration system of fluorine refrigerant is still the mainstream, but when selecting the type and power of cooling equipment, it is necessary to calculate the data for the installation of cold storage, and then make a high-quality choice.


KuchowePharmaceutical logistics cold storageWhat are your skills



When opening and drilling is required for the top warehouse plate or wall plate, the internal and external setting out and positioning shall be carried out according to the drawing design requirements, and the opening and drilling shall be carried out after review; The inlet hole, liquid inlet hole, return hole, water supply hole and drainage hole shall be opened with a hole opener. Construction treatment shall be carried out in time after opening and drilling, and the orifice shall be closed with foaming material or sealant to prevent air leakage and cold running; The door, vent and delivery port shall be decorated with wrapped edges and fixed with pull rivets, with a spacing of mm and mm outside.Online consultation,Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,No dirt shall be accumulated on the equipment of the fresh-keeping warehouse, otherwise the warehouse plate of the frozen warehouse will deform and endanger the thermal insulation characteristics, and keep the channels around the frozen warehouse unimpeded. Only by ensuring excellent heat removal and refrigeration can it be excellent. The place where the freezer is placed shall be kept dry, clean, free of inflammables and ensure that there is no risk of cutting. Objects shall not be stacked in front of the air conditioning evaporator to prevent endangering the actual effect of refrigeration. - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.Kuchowe, and the refrigerating capacity can not meet the load requirements of the warehouse: due to the long-term operation of the compressor, the cylinder sleeve, ring and other parts are seriously worn, the long-term cold storage installation installation, fruit preservation construction, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced, and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse,KuchoweHow much is the cold storage installed per square meter, the temperature of the warehouse will drop slowly.Watertight polyurethane rigid foam has low water absorption, good permeability to water vapor, and the obturator rate is more than %. It is a dense microporous foam material, and is not easy to permeate. It is an hydrophobic material.Regular oil discharge, descaling and air discharge: when there is a .mm thick oil film in the evaporator coil, in order to maintain the set temperature requirements, the evaporation temperature will decrease by ℃ and the power consumption will increase by more than ; When the scale on the water pipe wall in the condenser reaches mm, the condensation temperature will rise by ℃ compared with the original temperature, and the power consumption will increase. When the refrigeration system is mixed with non condensable gas and its partial pressure reaches .mpa, the power consumption will increase by about . It can be seen that it is cold

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

Comment area

share 4 Comments

user 938HP166090698 / 2024-01-16 10:09:34 / reply
The quality is very good, really good, KuchowePharmaceutical logistics cold storage the same as the picture, the packaging and quality are also very good,
user 695HP135175170 / 2024-01-16 11:11:05 / reply
Happy cooperation and tight packaging. Let’s talk about business services: Like
user 914HP134131469 / 2024-01-16 11:25:10 / reply
The logistics is very fast, look forward to working together again
user 965HP113924865 / 2024-01-16 10:27:41 / reply
KuchowePharmaceutical logistics cold storage I received it, the seller delivered the goods very quickly, the logistics is also very good, the customer service attitude is excellent, very patient, giving people a kind of intimacy, and I really like it. There are also exquisite packaging and high-end atmosphere. It can be seen that the merchants are very careful. KuchowePharmaceutical logistics cold storage It's really good, it matches the picture, there is no difference, it is really good value for money.

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links