category:energy / date:2024-04-05 01:26:19 / browse:56 / comment:4

- floor installation of cold storage: first level the floor,KafenbergInstallation price of cold storage board, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.Energy saving and power saving: the design cost of quick freezing warehouse mentioned above is very low, but it has a great impact on the cost of quick freezing warehouse and later use cost. The electricity bill is often an important expenditure item in the later stage. The design scheme of the show can greatly reduce the power consumption of the quick freezing warehouse. The selection of the back sunny side of the quick freezing warehouse, the selection of the thickness of the thermal insulation board should be appropriate, and the temperature difference between the adjacent cold storage rooms should not be too large are all issues that we need to consider. There are also some tips, such as the use of air curtain machine on the quick freezing warehouse door. We remind users to use parallel units in quick freezing warehouse as far as possible and start them reasonably.Kafenberg,Nowadays, the application of fresh-keeping storehouse is more and more extensive. It is closely related to our daily life. Fresh-keeping storehouse is mainly to ensure the freshness of food.If there is more air or refrigerant oil in the evaporator, the heat transfer effect will be reduced: once more refrigerant oil is attached to the inner surface of the evaporator heat transfer tube, the heat transfer coefficient will be reduced. Similarly, if there is more air in the heat transfer tube, the heat exchange area of the evaporator will be reduced, the heat transfer efficiency will be significantly reduced and the decline rate of warehouse temperature will be slowed down.Qorveh,Stretch perlite: stretch perlite is a kind of granular material with porous layout. The gap in it blocks out the heat. Professional cold storage installation, cold storage installation, cold storage construction fruit fresh-keeping cold storage, medical cold storage, strict testing, quality assurance. Preferential activities are in progress. Welcome to consult. It has a good heat insulation effect. Then, the water vapor in the cold storage is easy to condense, and the water absorption of extensional perlite is particularly strong. If it absorbs a lot of water, its nature will be greatly reduced. Therefore, it is necessary to be careful to select extensional perlite as cold storage.Technical assurance measures for the installation of cold storage: during production in the production workshop, the production shall be carried out in strict accordance with the operation rules specified in ISO quality operation, self inspection and inspection application shall be carried out to ensure that the factory pass rate is, and unqualified products are not allowed to leave the factory.Cold storage has good water tightness. Polyurethane rigid foam has low water absorption, good permeability to water vapor, foam holes, disconnected and closed porosity of more than %. It is a dense microporous foam material, and is not easy to permeate. It belongs to hydrophobic materials.


KafenbergMedical cold storageExpected overall price



Relative humidity maintenance of quick-frozen warehouse: humidification of quick-frozen warehouse is very important, from centrifugal humidification to high-pressure micro fog humidification, to the current ultrasonic humidifier. The utility model has the advantages of small particles, uniform humidification, no freezing and blocking, and no dirty blocking. The air conditioning humidifier we produce is specially designed for all kinds of vegetable and fruit quick freezing warehouses, which is essentially different from other humidifiers in the market: fully closed circulation, that is, take the gas in the warehouse, return to the warehouse through the humidifier and isolate it from the outside air.The ground should be flat and not uneven. If the ground is uneven, the ground of the warehouse must be leveled before the cold storage can be built and installed.The structure of contemporary cold storage is in the development trend of prefabricated building cold storage. It is made into prefabricated components of cold storage including steam barrier and heat insulation plate to ensure on-site assembly. Its advantage is that the project construction is convenient,KafenbergInstallation of small cold storage, rapid and movable, but the project cost is relatively high.Promotion, - floor installation of cold storage: first level the floor, then install the floor, select a beautiful floor and put it in a conspicuous place, and do a good job in the floor and evaporator drainage system.In the low temperature environment, especially in the periodic freezing and thawing cycle, the building structure is also vulnerable to. Therefore, the building materials of the cold storage and the structure of each part of the cold storage should have sufficient frost resistance.Installation of cold storage, construction of cold storage, fruit preservation cold storage and medical cold storage have stable, safe, reliable and maintenance free performance. The technical level has reached the domestic level and the advanced level of similar international products. If there is a large amount of ice and water, it must be cleaned in time and it must not be knocked during cleaning, so as not to damage the ground and affect the service life of the cold storage.


KafenbergMedical cold storageExpected overall price



Wall and floor fixtures shall start at corners. According to the plate layout drawing, transport the two plates at the corner of the required device to the device location. According to the plate beam height and the model of the angle iron for fixing the mushroom head nylon bolt, drill a hole at the corresponding elevation in the middle of the plate width. When drilling, the electric drill should be perpendicular to the plate surface. Put the mushroom head nylon bolt in the hole, and tighten it horizontally, so as to make the nylon bolt on the surface of the warehouse plate slightly concave. When setting up the wall panels, foam data and other soft data should be laid on the floor slots along with the floor of the storehouse, so as to avoid damaging the storehouse. After the two corner panels are neutrally removed from the floor, the plane position of the wallboard and the verticality of the storehouse should be adjusted in time according to the location of the laying line, and check whether the top elevation of the wallboard can be correct. After the position of the wallboard is correct, weld the angle iron on the plate beam and fix the inner and outer corners. When welding the angle iron parts, the angle iron parts of the warehouse plate shall be covered with a shield to avoid the high temperature of the welding ground baking the warehouse plate and welding slag on the warehouse plate during electric arc welding.Free consultation,During the use of cold storage, attention shall be paid to the collision and scratch of the storage body to avoid the depression and corrosion of the storage plate which will seriously reduce the local thermal insulation performance of the storage body.Evaporation temperature the sweating temperature of the refrigeration in the wafer machine needs to be lower than the air temperature in order to transfer heat from the engine room to the refrigerant. Usually, the temperature difference of room air conditioner is between C and C. If the temperature difference cannot be maintained due to adverse factors, the operation energy consumption will increase.Preparation, prepare the project planning of cold storage, and prepare the construction site and construction materials. All kinds of materials for cold storage construction are customized according to the needs of customers. Sort out the construction site that meets the requirements, check the material quality and model, and start the installation of cold storage after confirmation.Kafenberg,The equipment that needs to be installed in the warehouse and put into the warehouse shall be installed in place or placed in an appropriate position in the warehouse; The wall warehouse board shall be installed from the corner of the warehouse body, and the professional cold warehouse shall be installed. The cold warehouse shall be installed. The cold warehouse shall be constructed. The fruit fresh-keeping cold warehouse and medical cold warehouse shall have high pressure rating, good waterproof performance, fire and high temperature resistance, strong overload capacity, corrosion resistance, radiation protection and long service life. The corner shall be temporarily fixed with . color plate angle steel; When installing each wall panel, evenly apply two layers of foaming material on the joint surface of male and female groove and apply one layer of foaming material when installing polystyrene wall panel. The blanking shall be uniform and continuous; After the wallboard is installed in place,KafenbergHow much is a small cold storage, pull rivets at the lap joint of the internal and external steel plates of the two wallboards for connection and fixation, and the rivet spacing in the warehouse should be mm; When connecting the library plate in the form of eccentric hook connection, the eccentric hook shall be loosened once before installation to ensure reliable locking during installation.The efficiency of the compressor is low, and the refrigerating capacity can not meet the load requirements of the warehouse: due to the long-term operation of the compressor the cylinder sleeve, ring and other parts are seriously worn, the long-term cold storage installation, construction, fruit preservation, medical cold storage and other brand products, the designated products are complete, the quality is guaranteed, and the sealing performance will be reduced accordingly with the increase of the matching clearance, The gas transmission coefficient of the compressor will also be reduced, and the refrigeration capacity will be reduced. When the refrigerating capacity is less than the heat load of the warehouse, the temperature of the warehouse will drop slowly.Quick freezing storehouse is widely used. There are many kinds of temperature in quick freezing storehouse, and multi temperature or double temperature can be realized to meet the needs of different customers. Fault phenomena: unit current is large and voltage is too low; Loose wiring; The unit pressure exceeds the rated pressure; The oil separation core is blocked; Device failure; Host failure; Main motor fault; Fault phenomenon: the unit cannot be started and the fuse is broken; The temperature switch is broken; Loose wiring; Thermal relay of main motor acts; The thermal relay of cold storage fan motor acts; The transformer is broken; No power input (unit); Failure not eliminated (unit); The actuator is faulty.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

Comment area

share 4 Comments

user 530HP141750488 / 2024-04-05 09:16:22 / reply
Your service is very good, KafenbergMedical cold storage is also very cheap! I will come often in the future!
user 605HP153695373 / 2024-04-05 10:15:39 / reply
I heard a colleague's introduction to buy KafenbergMedical cold storage, and they all said that the quality is good, and I will come to your house next time. Ha ha.
user 60HP184127502 / 2024-04-05 09:10:02 / reply
The logistics is very fast, look forward to working together again
user 466HP159575805 / 2024-04-05 08:33:42 / reply
Make an advertisement for you, friends: This KafenbergMedical cold storage product is great value.

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links