The construction structure of structural cold storage can be brick concrete structure or steel structure, which can be determined according to their own budget and actual needs. At present most cold storages are constructed with single-layer steel structure, and are equipped with combined thermal insulation storage body, unloading platform, refrigeration system, system, pipeline system, etc. according to the actual needs of cold storage circulation.Requirements for the cold storage time of the device: the cold storage of the refrigeration system using ammonia as refrigerant shall be supported in the place with low population density around.Dario,Part of the cooling water system of ammonia stop valve shall clean the dirt in the water tank, remove and clean the nozzle.Cold storage board, compressor, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Berlin Schoeneberg,There are many kinds of cold storage. According to the material, it can be divided into color steel plate, stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, .mm ivory white, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, W = mm and W = . The dimensions of non-standard plates are different from those of Wa, WB and W.At ordinary times, users should check the sealing degree of the gap of the cold storage, and notify the cold storage for maintenance in time if damaged parts are found.The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, descaling and air discharge in the refrigeration system of the warehouse.Whether there is a problem with the line system of the first controlled atmosphere storage. After the line problem is eliminated, check whether the cold storage is overloaded. If there is a problem with the line, please deal with it in time. When the power is overloaded, the power or increase the square of the line.For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.Convenient and efficient,Polyurethane with good fire resistance and flame retardancy is a kind of refractory and self extinguishing material after adding flame retardant. In case of fire it can be carbonized, unlike flow burning and flashover like extruded board, which can effectively prevent fire spread. In particular, it can be sealed as a whole after systematic fire prevention treatment to form non combustible products.The products stored in the medical cold storage project must be managed by color code, so as to avoid the problem of purchase errors. In the process of handling, long service life and high comprehensive cost performance can reach more than years under normal use and maintenance conditions. Under the normal service conditions during the service life of the structure, it will not be affected by drying, or electrochemical corrosion, as well as the growth of insects, fungi or algae or rodents.
The polyurethane insulation board used in the construction of cold storage shall be integral and continuous, and there shall be no joint in the middle. The junction of polyurethane insulation board, top plate and ground shall be made into fillet arc for transition, which can well meet the health needs.total cost,DarioInstallation price of large cold storage, - Installation of the vertical plate of the cold storage: select the angle first according to the site conditions and locate it (i.e. lock the vertical plate and the floor) to extend to both sides at this angle. Only lock the vertical plate and the vertical plate and locate it when it meets the vertical angle. Put the beautiful plate in a conspicuous place. When installing it on the side of the evaporator, make the drainage pipe in advance, and make U-bend and silica gel outside the storage.The exhaust pipe and return pipe shall have a constant slope. When the condenser is higher than the compressor, the exhaust pipe shall slope towards the condenser and a liquid ring shall be installed at the exhaust port of the compressor. Prevent the gas from cooling and liquefying back to the high-pressure exhaust port after shutdown, and cause liquid compression during restart.How to maintain the refrigeration compressor in the cold storage in order to prolong its service life and reduce the occurrence of faults in the use process. The refrigeration compressor in the cold storage needs regular maintenance. Here we introduce the maintenance of the compressor in the cold storage.Dario,There are many kinds of cold storage. According to the material, it can be divided into color steel plate stainless steel plate and salted steel. Among them, color steel plate has strong anti rust ability, but stainless steel plate has strong anti rust ability, while salted steel has both beautiful appearance and anti rust ability. According to the layout, it is divided into flat plate and wave plate. The former is flat after the surface material is formed, and the latter is rugged after the surface material is formed. According to the thickness and color of surface materials, the thickness of stainless steel is .mm and mm, without color requirements; The thickness of salted steel plate is .mm, without color requirements; The thickness of PE paint baking board is .mm .mm ivory white,DarioVegetable and fruit cold storage, titanium white and white gray. The most important thing for the cold storage is the applicable temperature of the cold storage. It is divided according to the insulation thickness of the storage plate. The thickness of the sky floor of the mm storage plate is mm, and the thickness of the vertical plate is mm and mm, which is suitable for the insulation conditions of - ℃ ~ - ℃; mm storage plate: the thickness of the ceiling plate is mm and the thickness of the vertical plate is mm, which is suitable for the thermal insulation conditions of ℃ ~ - ℃. The thickness of the ceiling plate and the vertical plate of mm storage plate is mm, which is suitable for the thermal insulation conditions above ℃. In fact, there are many other classification methods of cold storage. Determined by the current processing technology, it can be divided into standard plate and non-standard plate according to the width and size range of warehouse plate, including standard plate vertical plate width wa = mm, heaven and earth plate width WB = mm, vertical angle plate W = mm, W = mm, WB and W.Cold storage board,DarioHow to install cold storage, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.The evaporator surface is too thick or too much dust, and the heat transfer effect decreases: another important reason is that the heat transfer efficiency of evaporator is low, which is mainly caused by excessive frost or excessive dust on the evaporator surface.
share 6 Comments
Comment / Cancel reply