Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).The common phenomenon of quick freezing storehouse is that the temperature of quick freezing storehouse can't drop down or drops slowly. Now, a simple analysis is made on the reasons for the slow drop of temperature: the cold capacity loss of quick freezing storehouse is large due to poor thermal insulation or sealing performance; the poor thermal insulation performance is due to insufficient thickness of thermal insulation layer of pipeline and warehouse thermal insulation wall, resulting in poor thermal insulation and thermal insulation effect, It is mainly caused by improper selection of insulation layer thickness in design or poor quality of insulation materials in construction.Saint Vincent and the Grenadines,If spraying is used, the tightness of warehouse doors and windows shall be considered.Cold storage board,Saint Vincent and the GrenadinesCold storage installation manufacturer, compressor, and other components in the cold storage can reasonably adjust the evaporation and condensation temperature, so as to improve the reduction of power consumption and reduce the production cost. Professional cold storage installation, installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, quality assurance, professional, timely supply and high cost performance. It has become the preferred brand for many wire products. Welcome to buy! Save more resources.Kroonstad,On the basis of cold storage and preservation, the quick-frozen warehouse increases the regulation of gas composition, inhibits the respiration of fruits and vegetables delays their metabolic process, better maintains the freshness and commercial quality of fruits and vegetables, and prolongs the storage period and shelf life of fruits and vegetables. Generally, controlled atmosphere storage of fruits can prolong the storage period by & mdash; Three times or more. OK, what is the standard of quick freezing warehouse?During the installation of polystyrene storehouse, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, the mm gap shall be marked with foaming material to ensure the sealing performance of the warehouse body.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).
The temperature and humidity in the warehouse shall be kept uniform without movement; Try to finish the food in the warehouse at one time.Due to the slow cooling, all equipment will consume electric energy during operation. If the cooling is slow, the equipment will stop and cannot consume electricity so the electricity charge will not be consumed. As a high energy consuming equipment, the daily power consumption of cold storage is relatively large. If the refrigeration effect is not good, the annual use cost will directly double several times. Moreover, if the equipment operates for a long time, the service life will be reduced accordingly, which is something users don't want to see.In order to prevent damage to the cold storage, it is necessary to lay some foam on the floor of the cold storage tank.Installation material list,Cold storage has good water tightness. Polyurethane rigid foam has low water absorption good permeability to water vapor, foam holes,Saint Vincent and the GrenadinesHow much is it to install a cold storage, disconnected and closed porosity of more than %. It is a dense microporous foam material, which is more dense than air surface, and is not easy to permeate. It belongs to hydrophobic materials.The machine room of ammonia refrigeration system shall be equipped with exhaust assembly; The exhaust fan shall adopt anti motor. When the power supply is cut off due to unexpected refrigeration, it shall be able to ensure the reliable power supply of the exhaust fan. The overload protection of the exhaust fan should be applied to the signal alarm system without directly stopping the exhaust fan. The button box of the exhaust fan shall be concealed in the wall outside the ammonia compressor room.Indirect cooling is that the air in the warehouse is pumped into the air cooling device by the blower. The air is absorbed by the evaporation pipe circling in the cooling device, and then sent to the warehouse for cooling. The advantages of air cooling are rapid cooling, uniform temperature in the warehouse, and can bring harmful gases such as carbon oxide out of the warehouse during storage.
Reasonably adjust the cold storage evaporator and defrost in time: Generally speaking every ℃ increase in the evaporation temperature of the cold storage can save energy by ~ . Therefore, on the premise of meeting the refrigeration process of the product,Install the temporary lighting facilities in the warehouse, and do a good job in rain proof, moisture-proof, anti-collision, anti binding and other safety protection.Refrigerated vehicle planning Kende refrigeration reminds enterprises with the construction needs of logistics refrigerated warehouse project to conduct in-depth communication with the project and refrigerated vehicle planning on warehouse location and actual use needs when determining the final installation construction mode, so as to ensure the smooth circulation of goods in logistics refrigerated warehouse.For the flushing (thawing) drainage pipe in the cold room with different temperature, an exhaust valve equipment shall be set before connecting the flushing (thawing) drainage pipe.Saint Vincent and the Grenadines,Before the acceptance and delivery of the project,Saint Vincent and the GrenadinesPrice of fruit preservation warehouse, the board surface shall be wiped clean. If there is any scratch, the Perpendicularity Error of wall plate shall be corrected while the top storehouse plate is installed. The length of the top warehouse plate shall be mm shorter than the surface of the wall plate. After the installation of the top warehouse plate, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.
share 4 Comments
Comment / Cancel reply