category:energy / date:2024-04-15 01:37:33 / browse:57 / comment:4

When the cold storage is used for the first time or shut down for a long time, it needs to be cooled in stages to avoid sudden changes in the temperature difference inside and outside the warehouse, resulting in the warehouse body.Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.Hard,The valve temperature sensing package shall be fastened at the evaporator outlet with a metal clamp for mm & mdash; mm, tightly wrapped with double-layer insulation.The factors affecting the installation cost of cold storage are as follows: cold storage construction: the site selection shall comply with laws and regulations and meet the relevant requirements for food hygiene and. And pay attention to protecting the environment and ecological balance. In addition,HardFruit preservation cold storage, it shall be conducive to production, construction and dry ceremony.Bumpe,Commissioning cold storage. After all parts of the cold storage are installed and connected, the cold storage can be started for cold storage commissioning. According to the needs of customers, the cold storage can reach the predetermined temperature, the cooling speed and the operation of the cold storage are normal, and the cold storage can be delivered for use. The cold storage installation unit shall also provide the cold storage user with training on cold storage use and management knowledge, as well as some after-sales training.Fault phenomenon: high current or tripping during unit startup, and problems of user air switch; Input voltage is too low; The star angle conversion interval is too short (it should be ~ seconds); Hydraulic cylinder failure (no reset); Intake valve failure (too large opening or stuck); Loose wiring; Host failure; Main motor fault; TR time relay is broken (relay unit).Different food processing technical processes for the construction of cold storage are combined with local urban planning. The construction of cold storage is the design requirements and construction of cold storage, which not only avoids the cross pollution between foods, but also ensures its transportation facilities: within the construction scope, a reasonable overall layout, saves land and reduces costs.


HardHow much does it cost to install the cold storageIt needs to be launched step by step



The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.Establish a perfect computer network to realize the scientization of refrigeration supply chain distribution and traceability. In the European Union, the United States and Japan, all members of the food supply chain have the legal responsibility to implement traceability.Emergency measures during the use of the medical cold storage project, it may also encounter power failure or power failure. In fact, most medical cold storage projects will be equipped with emergency equipment, so that the medical cold storage project can achieve the effect of normal power supply. Once the automatic temperature or humidity monitoring system is abnormal, the cold storage door should be closed in time, So as not to expose more air conditioners, resulting in corresponding problems in the quality of stored products. The medical cold storage project also has a self rescue system in time. If the temperature of the cold storage exceeds the limit,HardLibrary installation, the system cooling system will also be turned on. When the temperature returns to normal, it will be automatically turned off.knowledge,The closed cell structure and surface material of polyurethane rigid foam with good moisture-proof, waterproof and corrosion resistance make it have better air resistance and water vapor resistance, and it can be made into inlaid connection structure during forming, which is easy to assemble. It does not need additional insulating layer to prevent moisture and saves a lot of trouble in laying insulating layer.Compression refrigerator is commonly used. It is mainly composed of compressor, condenser, throttle valve and evaporation pipe. The evaporation pipe is installed in the refrigeration warehouse. When the liquid coolant passes through the evaporation pipe, it directly absorbs the heat in the warehouse and cools down.Airtight construction of quick freezing storehouse: the modified atmosphere fresh-keeping storehouse is developed on the basis of the traditional high-temperature fresh-keeping storehouse, which has the & ldquo; Refrigeration & rdquo; Function, long-term cold storage installation, cold storage installation, fruit fresh-keeping cold storage, medical cold storage, complete products, excellent quality and favorable price. There are also & ldquo; Air conditioning & rdquo; Function; However, the quick freezing storehouse is not a simple superposition of ordinary high temperature storehouse and air conditioning equipment. In order to adjust the gas composition in the storehouse quickly, it is necessary to ensure that the quick freezing storehouse has good air tightness. This has been confirmed by the theoretical research and a large number of practical experience of quick freezing warehouse.


HardHow much does it cost to install the cold storageIt needs to be launched step by step



The overall construction achievements of the cold storage project have been put into use and the service life can reach years.how much,Install the library body. Generally, without hollow feeling compact and solid, load-bearing, antifreeze, moisture-proof, etc.Transportation: before the installation of the fresh-keeping storehouse, check the number of storeboards of the fresh-keeping storehouse according to the delivery note. When loading and unloading the warehouse board, handle it with care, and lay an anti scratch layer on each layer of the warehouse board and the ground joint.Families will also be equipped with some simple refrigeration devices. For refrigeration devices such as cold storage, and in the production process of cold storage there will be no condensation in the cold storage of the plant. Condensation inside the cold storage or inside the insulation layer is harmful. Irreversible damage or deformation occurs in the new external insulation, and the external surface temperature of the external wall changes sharply. For example, the insulation and sound insulation effects of polyurethane insulation board are relatively good, which can be used in many industries. As we all know, the cold storage has great requirements for the thermal insulation effect of building materials. If the thermal insulation effect of building materials is not good, the cold storage will consume more energy during operation, and can not guarantee a good refrigeration effect. The performance of polyurethane insulation board meets the construction requirements of cold storage, so a large number of polyurethane insulation boards need to be used in the construction of general cold storage. Next, let's understand the physical properties of polyurethane insulation board.Hard,Preparation, prepare the project planning of cold storage, and prepare the construction site and construction materials. All kinds of materials for cold storage construction are customized according to the needs of customers. Sort out the construction site that meets the requirements, transport all installation materials to the construction site check the material quality and model, and start the installation of cold storage after confirmation.The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance,HardWhat are the cold storage installation companies, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.Thermal insulation rigid polyurethane has low thermal conductivity and good thermal performance. When the density of rigid polyurethane is ~ kg / m, the thermal conductivity is only . ~ .w / (m.k), which is the lowest among all thermal insulation materials at present.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

 Articles that may be of interest

Comment area

share 4 Comments

user 78HP121928405 / 2024-04-15 09:20:27 / reply
The stuff is really good, but HardHow much does it cost to install the cold storage the price is a bit more expensive, but it is still worth the money. This is the first time I bought it, thanks to your shopping guide.
user 695HP135175170 / 2024-04-15 10:28:04 / reply
Buying things online is about integrity, and you do it! Thank you HardHow much does it cost to install the cold storage Like one Fast delivery, very good attitude, very satisfied! very good!
user 535HP136858825 / 2024-04-15 08:54:46 / reply
So give praise! Just received the goods, very good, HardHow much does it cost to install the cold storage great value for money! ! Come in the future!
user 632HP195506591 / 2024-04-15 10:37:13 / reply
Since the last time I bought your HardHow much does it cost to install the cold storage, this new model has indeed met the standard and is very good, giving you a good comment.

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links