the stored goods must be in strict accordance with the relevant regulations. The goods should have a certain distance from the ground and wall of the cold storage. When stacking the cold storages using their white materials have significantly lower power consumption than those using other white materials.During the use of the goods yard medical cold storage projectcategory:energy / date:2024-04-15 00:28:12 / browse:37 / comment:6
These measures have achieved quite good results. Compared with several cold storages at a customer in Jining, the distance between the goods and the goods must be cm. At the same time, the distance between the goods and the cold fan should also be cm. No goods can be stored within this range, This is also an important content in the use of medical cold storage engineering.Eisenstadt,The location of fresh-keeping warehouse installation shall be in a stable and convenient place; (if it is a local fruit farmer, it should be installed near the fruit source)As a coolant, make it evaporate under low pressure and mechanical conditions to absorb the heat in the storage, so as to achieve the purpose of cooling.Trabzonspor,Polyurethane foam: This is also a very common cold storage material. It has strong thermal insulation effect and strong mechanical strength. Now it is widely used and has a good application prospect.The polyurethane insulation board shall be connected by plug-in notch connection, because it has higher strength when connecting in this way.The cold storage board uses light polyurethane as the inner material of the cold storage board. The advantage of polyurethane is that the thermal insulation performance is very good. The exterior of polyurethane cold storage board is composed of SII, so as to make the cold storage more energy-saving and improve the working efficiency of cold storage.
Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.For the selection of air conditioning units, it is necessary to consider the condensation pressure and other related problems of the unit, increase the proportion of outdoor cold air, and achieve the effect of energy saving.Floor insulation of medium-sized cold storage the structure of medium-sized cold storage is what we often call the surface, that is, the top and wall are made of color steel plate / stainless steel with appropriate thickness of polyurethane and other insulation materials,EisenstadtPharmaceutical cold storage project, while the ground needs to be insulated separately. At present, the common operations in the market are: laying the ground with XPS extruded board, laying moisture-proof and steam isolating SPS materials above and below the extruded board respectively, and then pouring concrete or reinforced concrete.How much does it cost?,Proper protective measures shall be taken during transportation to prevent plate from being strangled and scratched.Cold storage is fireproof, flame retardant and high resistance. Professional cold storage installation, cold storage installation, cold storage construction, fruit preservation cold storage, medical cold storage and other special products old brands, price advantages and guaranteed quality. Polyurethane is a flame retardant self extinguishing material after adding flame retardant. Its softening point can be above degrees Celsius and will only be decomposed at higher temperatures. In addition, the ash formed on the surface of polyurethane will be in its foam, polyurethane will not produce harmful gas at high temperature.The construction of cold storage in site selection bears the circulation of low-temperature goods. Therefore, the transportation convenience of cold storage construction site should be given priority in site selection, such as proximity to roads, railways, etc. At the same time, the location of the cold storage should avoid large pollution sources and direct sunlight, and the construction of the cold storage should have good drainage and ventilation conditions.
The cold storage belongs to a kind of refrigeration equipment. Compared with the refrigerator, its refrigeration area is large, but they have the same refrigeration principle. So how to maintain the cold storage every day. Today I'll introduce how to do a good job in the daily management and maintenance after the installation of the cold storage.Potential development,Whether the parameters of refrigeration equipment are consistent. When the cold storage leaves the factory, the temperature and temperature difference parameters of the cold storage shall be customized according to the user's requirements. After understanding the technical parameters of the cold storage, set the parameters on the refrigerator. During use, the air humidity is high and the defrosting interval is long. The common cold storage boards of cold storage include mm, mm, mm, mm and mm polyurethane thermal insulation boards, color steel tiles, stainless steel plates, salt thick steel plates, embossed aluminum plates,EisenstadtInstallation price of cold storage, polyurethane spraying, etc. on both sides or single and double sides, which have light weight, high compressive strength, good fire resistance, corrosion resistance and aging resistance, The cold storage board is simple and convenient to assemble, and is a wide range of raw materials selected for the heat insulation and heat preservation of the cold storage. The cost of stainless steel plate and salt plate increases, and it is also easy to deform and damage the appearance.When adjusting the station, each outlet pipe shall be sawn into a degree inclined mouth to the bottom, if the supporting steel beam has been installed in the warehouse, the top warehouse plate and the supporting steel beam shall be fixed with pull rivets during the installation of each warehouse plate and each top warehouse plate shall be riveted in two rows; If the lifting point type is adopted, the installation and construction of the lifting layout shall be realized before the installation and construction of the top silo plate, so as to ensure that each lifting point can be installed at the same time during the installation of the top silo plate; The lifting point shall ensure that there are at least two points along the width direction of each warehouse plate.Eisenstadt,Drainage measures shall be provided for the villa room and overhead layer of the road surface of the cold storage engineering building.During production in the production workshop, the unit weight of Pu warehouse board shall not be less than the unit weight required by the project, not less than & plusmn; kg/m.The combined cold storage door starts frequently or does not start for a long time, or does not stop for a long time, or stops before the storage temperature reaches.
share 6 Comments
Comment / Cancel reply