category:energy / date:2024-01-04 03:34:25 / browse:74 / comment:4

The type of cold storage to be built in the type of cold storage should be determined according to the type of circulating goods. For example,Monday repurchaseSmall cold storage installation company, while the cold storage with refrigeration + freezing will be built if there are many types of circulating goods and great difference in storage temperature. As for the size of the cold storage, it should be determined according to the type, quantity, frequency, cycle, whether to use shelf stacking and so on. For example, for fruits and vegetables packed in cartons, the storage capacity of -kg per cubic meter can be referred to, and the size of cold storage construction can be estimated in combination with the storage capacity rate of about .-..After the cold storage at the corner is installed, the next cold storage can be installed along the direction of the corner. Adopt the similar installation of Zhang cold storage to install the thermal insulation board of the storage. Professional cold storage installation installation of cold storage, cold storage construction, fruit preservation cold storage, medical cold storage, advanced technology, more affordable price and more preferential. Welcome to consult. Pay attention to its compactness and continuous uniformity.Monday repurchase,Refrigerated vehicle planning Kende refrigeration reminds enterprises with the construction needs of logistics refrigerated warehouse project to conduct in-depth communication with the project and refrigerated vehicle planning on warehouse location and actual use needs when determining the final installation construction mode, so as to ensure the smooth circulation of goods in logistics refrigerated warehouse.The new cold storage material is made of rigid polyurethane or polystyrene foam insulation sandwich panel,General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.Feasibility of the design scheme: the design of the quick-frozen warehouse can not be taken for granted. Many restrictive factors should be considered. In practice, a reasonable design scheme should be given according to local conditions. For example, the large-scale quick-frozen warehouse I built for my family should be refrigerated with ammonia in theory, because the refrigeration capacity of ammonia refrigeration is large, and I found that it is cheap to replicate cold through actual field investigation.Cold storage, compressor overload, lack of refrigerant, low pressure too low,Monday repurchaseConstruction and installation of cold storage, compressor jamming.


Monday repurchaseDesign of pharmaceutical cold storageAbility to protect



The two sets of connectors between the cold storage shall be wedged tightly, and the two sets of connectors shall be fixed at the upper, outer and lower sides of the cracks in the cold storage respectively. The lower connector shall be as close as possible, so as to facilitate the use of concrete to cover the connector in the future.After the fresh-keeping storehouse is built, it is also important to pay special attention to the maintenance of fresh-keeping storehouse equipment in the whole process of application. Here are some key maintenance matters.Frequently observe the operation state of the heart compressor of the cold storage equipment and its exhaust temperature. During the season change operation, pay special attention to the operation state of the system and adjust the liquid supply and condensation temperature of the system in time.details,Monday repurchaseHow much is the installation of cold storage equipment,For the ground insulation of large cold storage, we can that the ground insulation of medium-sized cold storage is more complex than that of small cold storage, and the ground insulation operation of large cold storage with larger warehouse area will be more complex. The common operations are as follows: first lay the ventilation pipe to prevent the ground from freezing drum cracking, then lay the XPS extruded plate (staggered laying is required when laying the extruded plate), then lay the moisture-proof and vapor barrier on the upper and lower sides of the extruded plate, then pour the reinforced concrete (generally at least cm thick), and then make the emery floor or epoxy floor according to the requirements. Among them, the XPS extruded plate is also laid according to the warehouse temperature. For example, the XPS extruded plate with thickness of ~ mm needs to be laid in the general low-temperature cold storage, while the XPS extruded plate with thickness of ~ mm can be laid in the high-temperature cold storage.Requirements for refrigeration equipment in quick freezing warehouse: the strict sealing of quick freezing warehouse is obviously different from that of ordinary quick freezing warehouse. Therefore, how to seal the refrigeration equipment is the key. First of all, all through wall pipelines must be equipped with sleeves, the frost flushing water return pipeline must be equipped with U-shaped bend water seal and the main frost flushing and return pipeline outside the warehouse shall be equipped with air filling port to prevent the gas in the warehouse from being pumped out of the warehouse by negative pressure. In addition, due to the good sealing of the quick freezing warehouse, the set fluctuation range of the warehouse temperature should not be too large to prevent excessive positive and negative pressure from damaging the warehouse body.The combined cold storage does not cool or the cooling effect is poor. Check whether the condenser of the refrigerator is dirty. Whether frost is too thick on the evaporator in the warehouse. Check whether the refrigerant is leaking (apply soapy water to the pipeline connection, and if bubbles are generated, it indicates that the refrigerant is leaking). And ask the combined cold storage engineering personnel to supplement the refrigerant and deal with the leakage. Check whether the sealing of the combined cold storage door is intact and eliminate it. Whether the refrigerator of the combined cold storage works. Whether the parameter setting of the computer controller of the cold storage is correct, and reassemble the cold storage door for installation. Check whether the cooler in the cold storage fails and replace it. Whether there is enough clearance for stacking articles in the warehouse and dredge them.


Monday repurchaseDesign of pharmaceutical cold storageAbility to protect



The insulation board of the cold storage adopts polyurethane double-sided color steel plate. The main effect of this cold storage insulation board is good sealing performance, insulation effect and moisture-proof effect, so as to ensure the refrigeration effect of the cold storage. The electric cold storage door is adopted for the cold storage door, and the cold storage management personnel can timely and effectively open and close the door when entering and leaving, so as to avoid the loss of refrigeration capacity of the cold storage.Installation materials,Insufficient refrigeration dose and capacity in the system: there are two main reasons for insufficient refrigerant circulation,Good heat dissipation, good refrigeration. Do not stack sundries around the refrigeration unit The electrical equipment of the fresh-keeping warehouse equipment shall be protected from moisture and electric shock caused by electric leakage. The hinge, handle and door lock of the fresh-keeping storehouse shall be regularly added with oil according to the actual situation. The electrical equipment maintenance of the fresh-keeping storehouse equipment shall be operated by electricians or personnel who know the common sense of electricity. Any maintenance must cut off the power supply to ensure safety.The foundation of cold storage is affected by low temperature, and the water in the soil is easy to be frozen. Due to the volume of frozen soil, the ground will be broken and the whole building structure will be deformed. If the damage is serious, it may even make the cold storage unusable. Therefore, in addition to the thermal insulation layer the floor of low-temperature cold storage must be treated under the thermal insulation layer to prevent soil freezing. The bottom plate of the cold storage shall stack a large number of goods and pass through various loading, unloading and transportation machinery and equipment. Therefore, the structure of the cold storage plate shall be firm and have large bearing capacity. In low temperature environment, especially in the process of periodic freezing and thawing cycle, building structures are vulnerable to. Therefore, the structure of each part of the cold storage and the building materials of the cold storage should have sufficient frost resistance.Monday repurchase,The equipment configuration is reasonable and the service life of the quick freezing warehouse is long. The reasonable equipment configuration of the quick freezing warehouse can greatly prolong the service time of the quick freezing warehouse. Some compressors are easy to be damaged when they work at full load for a long time, so we try to use screw parallel units. The great advantage of this unit is that it can turn on all equipment, just like the shift at work, so that the compressor can work and rest in turn.General quick-frozen warehouses are mostly cooled by refrigeration mechanisms, and those with very low gasification temperature are used as coolant to evaporate under low pressure and mechanical conditions, so as to absorb the heat in the warehouse, so as to achieve the purpose of cooling and reduction.For water-cooled units, the turbidity of cooling water shall be frequently the cooling water shall be replaced frequently, and whether the running emitting, leakage and other conditions of the water supply system exist.

Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

 Articles that may be of interest

Comment area

share 4 Comments

user 695HP135175170 / 2024-01-04 11:44:22 / reply
Monday repurchaseDesign of pharmaceutical cold storage It’s really good, how long does it take to arrive after the departure?
user 391HP142030639 / 2024-01-04 10:52:59 / reply
You Monday repurchaseDesign of pharmaceutical cold storage are okay, give a discount next time you buy, and buy your company's Monday repurchaseDesign of pharmaceutical cold storage
user 173HP199071655 / 2024-01-04 11:52:41 / reply
A good seller, even a novice, a lot of Monday repurchaseDesign of pharmaceutical cold storage don’t understand. Fortunately, the seller has patient guidance on the other end of the computer, and I have a sense of accomplishment, and finally figured out the problem that I didn’t understand.^- ^Learn more in the future!
user 535HP136858825 / 2024-01-04 11:29:03 / reply
Although Monday repurchaseDesign of pharmaceutical cold storage has not yet arrived, I am looking forward to it, and the inquiry is still in transit.

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links