category:Machinery and industry equipment / date:2024-04-22 00:50:37 / browse:35 / comment:5

strictly speaking the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.Warsaw,. Different types of civil engineering traction elevators, screw elevators,WarsawHydraulic flipper manufacturer, and hydraulic elevators have different requirements for civil engineering. Common traction elevators require a certain amount of hoistway space, which can be made of concrete, steel structure hoistways, and glass curtain walls to create sightseeing elevators; The depth of the pit should be at least cm or more; Additionally, there are certain requirements for the height of the top floor.The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.Bengal,Measure the length, and depth of the pit (if any), and observe whether there are grooves and embedded parts at the support beam.The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.The front room of the fire elevator is equipped with indoor fire hydrants.


WarsawVertical hydraulic elevatorHow to judge the quality



Machine room power supply: The power supply should be three-phase V, HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersHousehold elevators must be regularly maintained to confirm their safety and whether they can continue to operate, while also repairing any faults and hidden dangers found.Tower style residential buildings above; Residential units and corridors with twelve or more floors; Other Class II public buildings with a building height exceeding meters; High rise buildings with elevators exceeding meters in height; The functional fire elevator has a front room. The area of the independent fire elevator front room is: the front room area of the residential building is greater than square meters; The front room area of public buildings and high-rise factory (warehouse) buildings is greater than square meters. When the front room of the fire elevator is shared with the smoke proof staircase, its area is: the area of the shared front room in residential buildings is greater than square meters, and the area of the shared front room in public buildings and high-rise factory (warehouse) buildings is greater than square meters.How much is it,WarsawFixed lifting stage,WarsawSecond floor household elevator,The safety monitoring machine room environment screen cabinet main power switch traction wheel speed limiter shaft and pit guide rail layer door and car counterweight should be reliably fixed with pressure plates to prevent loosening.The treatment of general civil engineering problems on escalator sites: the beam edge distance is too large: in this case, the length of the upper and lower platforms of the escalator can be increased to meet the actual dimensions of civil engineering. One platform can be extended on one side, or both platforms can be extended simultaneously. The total extension of the upper and lower platforms should generally not exceed mm. When lengthening the platform, attention should be paid to the length of the pit or the opening of the floor slab, which should also be lengthened at the same time. After the escalator is extended, support needs to be added in the middle of the escalator truss. In addition, changing the angle of the escalator from degrees to degrees can also make the beam edge distance longer.The mechanical components of the elevator's traction machine require oil. There are two scales on the outer cover of the traction machine. Open the oil nozzle to check that the oil should be in the middle of the two scales. If the oil is lower than the lower scale it means that the traction machine should be refueled. If not refueled, the elevator will not operate well for a long time, leading to the burning of the elevator traction machine and motor. After the elevator has been running for a long time, the oil should be replaced in a timely manner to keep the traction machine clean and in good condition.


WarsawVertical hydraulic elevatorHow to judge the quality



There are dedicated operation buttons for firefighters at appropriate positions at the entrance of the first floor elevator. The operation buttons are generally protected by glass sheets and have a red&# quo; mark in place; Dedicated to fire protection; Words such as.production,The basic content of escalator shaft measurement is to measure the lifting height. The same as measuring the height of a straight ladder, strictly speaking, the lifting height of a ladder is the vertical distance between the finished ground at the upper and lower support beams. When using the suspension line method to measure, attention should be paid to whether there is a drop between the positioning point of the line drop and the decoration surface of the lower support beam of the ladder.The elevator stops on a certain floor for a long time without moving or responding to external calls: it is possible that the elevator administrator has activated the driver operation function.When the normal power supply is cut off, the lighting inside the non fire elevator has no power, while there is still lighting inside the fire elevator.Warsaw,The requirement for the shaft is that it should not be plastered, which is beneficial for reducing noise, but there should be no protruding foreign objects.Machine room power supply: The power supply should be three-phase V HZ, and the lighting power supply should be single-phase V, HZ. The incoming line should be connected to the vicinity of the machine room entrance and equipped with an incoming socket. Specializing in product and renewable resource business, including: home elevator manufacturersThe effective support width of the upper and lower support beams should be greater than the width of the escalator truss, and there should be embedded steel plates.


Copyright Notice: This article is not authorized by any Creative Commons agreement, you can freely reprint or use it in any form

Comment area

share 5 Comments

user 779HP136589660 / 2024-04-22 08:33:36 / reply
Let me talk about the quality of the goods first: WarsawVertical hydraulic elevator Overall it is good, and the packaging is tight. Let’s talk about business services: Like it. Last review express: delivery is fast. The other is to thank the store for discounts, after all, cheap and good products are more real. I hope that the store will give more discounts and notify old customers in time to promote repurchase. I wish business prosperous.
user 965HP113924865 / 2024-04-22 08:14:25 / reply
Let me evaluate this WarsawVertical hydraulic elevator, the price is good, the quality is good, the delivery is good, and the boss is good.
user 984HP143755493 / 2024-04-22 08:58:39 / reply
WarsawVertical hydraulic elevator It can be said to be top-notch, and the details are perfect.
user 409HP184720764 / 2024-04-22 08:44:00 / reply
I just received it in the morning and my friends like it very much. I will buy it from you next time WarsawVertical hydraulic elevator.
user 256HP158312377 / 2024-04-22 08:57:18 / reply
WarsawVertical hydraulic elevator It’s really good, how long does it take to arrive after the departure?

Comment / Cancel reply

Required

Optional

Optional

◎Welcome to discuss, please express your views here.

Hello, welcome to this website!

Label list

Links